Norway · July 2026
Oslo (Alna River) and Municipality of Tromsø, Norway
River and urban water quality monitoring systems
Sudden pollution caused by urban drainage is detected instantly on the Alna River; in Tromsø, measurement continues without interruption despite the Arctic climate.

Scope
A water quality monitoring system with a circulating measurement cell, measuring pH, TSS, colour, COD, dissolved oxygen, temperature and conductivity, was installed in Norway. A compact measurement station with pumped circulation was placed on the bank of the Alna River near Oslo.
Requirements and challenges
- Capturing sudden pollution changes caused by urban drainage and rainfall
- Uninterrupted measurement in Arctic conditions (low temperatures, risk of freezing)
- Continuous data logging for long-term evaluation
- Client
- Oslo (Alna River) and Municipality of Tromsø, Norway
- Location and date
- Norway · July 2026
- Sector
- Municipalities and water utilities
- Sensors
- pH, TSS, colour, COD, dissolved oxygen, temperature, conductivity; circulating measurement cell, automatic cleaning
- Software / hardware
- Remotely accessible monitoring infrastructure, continuous data logging